Additional Modules |
| 3-D Deconvolution |
- Nearest Neighbor
- Multiple Processor Optimization
- Speed Optimized
- Constrained Iterative
- Noise Smoothing
- Edge padding
- Individual Channel Programmability
- PSF Guide
- PSF Database
- Uses Calculated or Measured PSF's
- Speed Optimized
- Programmable Batch Deconvolution
|
| TTL Synchronization |
- TTL Control Hardware
- TTL Start of Image Capture
- Pushbutton Control of TTL Out During Image Capture
- Automatic TTL Pulse During Image Capture
- Record External TTL Pulses during Image Capture
- Includes Hardware for Pulse Generation and Recording
|
| Particle Tracking |
- Tracks objects in 2D and 3D
- Automatic and manual path (trajectory) delineation
- paths can be displayed as overlay on original data
- Statistics can be generated on a per-timepoint basis, such as position, mean intensity, instantaneous speed, instantaneous angle
- Statistics can be generated on a per-path basis, such as overall displacement, duration, mean speed, mean squared displacement, and diffusion
|
| Multi-Well Plate Module |
- User Selectable Configuration
- Well Visitation
- Visitation Frequency
- Integrated Autofocus Per Well
- Image Storage by Well
- Ability to Save Expirement Template Files
|
| FRET/Ratio/Densitometry (FRD) Module |
- Ratio Capture and Analysis
- Real-time Ratio Region Tracking and Graphing
- Regions to Mask Transfer
- Supports Simultaneous Ratio Capture (e.g. FURA-2 and BCECF)
- FURA-2 Calibration Guide
- Immediate Display of Automated Ratio Values or Ion Concentration
- Analytical Graphing Tools
- Multiple Camera / MultiSpec Imager enabled
- Acceptor Photobleach FRET Capture and Analysis
- Automatic Bleach Capture Script
- Automatic FRET Computation
- Gated Pseudocolor Display
- Track FRET by Object or Pixel
- Background Subtraction
- Sensitized Emission FRET Capture and Analysis
- Live Corrected FRET Image Generation
- Background Subtraction
- Channel Bleedthrough Calculation
- FRET Calibration Guide
- Gated Pseudocolor Display
- Track FRET by Object or Pixel
- Densitometry Capture and Analysis
- Interactive Calibration Guide
- Multiple Curve Fits
- Calibrations can be Saved and Applied to Multiple Images
|
| CellNet™ Pattern Recognition Module |
- Train Custom Neural Network Kernels
- Ability to Save Kernels and Apply to New Images
- Whole Cell and Subcellular Object Recognition by Morphometry
- Whole Cell and Subcellular Object Recognition by Channel Correlation
- Supports 2D, Time-lapse, 3D and 4D Data
|